vme-mxi-2. D-Size / 9U x 340mm. vme-mxi-2

 
 D-Size / 9U x 340mmvme-mxi-2  Run VIC, select VME device address, go to Interrupt tab

Configuration: P/N: PWA-90/333B Board Level Primary IDE and Floppy Interface Board Level Male and Female Secondary IDE Interface Board Level and Front Access SCSI Interface (2) 10/100 Ethernet InterfacesPart Number: VPSI2, VPSI2-2, Y261 A24 502, ES1201, ES1201. National Instruments VME-MXI-2 VMEbus Extender. Simultaneous-Sampling Multifunction DAQ National Instruments PCI-MXI-2 Interface Card National Instruments GPIB-USB-HS Controller for USB National Instruments 778647-01 Replacement Power Supply and Fan Shuttle for NI PXI-1044/PXI. When we bought the VXI-MXI-2 and VME-MXI-2, th ey came complete with register descriptions etc. Manufacturing . Page 1 VXI/VME Getting Started with Your ™ VXI/VMEpc 600 Series for Windows 95/NT VXI/VMEpc 600 Series for Windows 95/NT May 1998 Edition Part Number 321882A-01. 2 Replies 2588 Views 0 Kudos. National Instruments PXI-8145RT Embedded PXI Computer. The VXI-MXI-2 is used to extend the VXIbus. Active Participant. CompactRIO / CompactDAQ. . This card can also function as the MXIbus System Controller. Mercury Computer Systems RACE MCJ6 VME64 Motherboard. VME-MXI-2 PLCs/Machine Control from NATIONAL INSTRUMENTS 2-Year Warranty, Radwell Repairs - DISCONTINUED BY MANUFACTURER, PC MODULE, MACHINE CONTROL, RACK MOUNTED, VMEBUS EXTENDER, OPTIONAL 4 MB DRAMVME-MXI-2 Functional Description In the simplest terms, you can think of the VME-MXI-2 as a bus translator that converts VMEbus signals into appropriate MXIbus signals. Phone: (217) 352-9330. SYS68K / IBC-20/40-E08 High-Performance Controller Board Emerson / Motorola / Force Computers SPARC/CPU-5V/16-110-2 VME Single-Board Computer Emerson / Motorola / Force Computers SYS68K CPU-40B/4-01 Single Board. The National Instruments VME-MXI-2 interface board is a 6U, single-slot VMEbus extender based on MXI-2 technology. The DDrive module may be configured with one or two 2. National Instruments cFP-2120 Compact FieldPoint Ethernet Controller Interface. 0 MHz. National Instruments VME-MXI-2 VMEbus Extender. VME-MXI-2 Mainframe Extender, Remote Control Module for VXI—The Remote Control Module for VXI is a flexible, high-performance solution for stand-alone computer control of VXI systems. A-Size / 3U x 160mm. are not included with this equipment unless listed in the above stock item description. B-Size / 6U x 160mm. A-Size / 3U x 160mm. National Instruments VME-MXI-2 VMEbus Extender. ISA. A-Size / 3U x 160mm. The NI-VXI bus interface software for the PCI-MXI-2 and Solaris 2. EPC-6A High-Speed VMEbus Controller Microchip / Bancomm bc635VME Time and Frequency Processor National Instruments VME-MXI-2 VMEbus Extender Abaco Systems / SBS / Greenspring. Part Number: PF072100-R61. PCMCIA / CardBus. Also for: Pci-mxi-2, Vxi-mxi-2, Vme-mxi-2. National Instruments VXI-MXI-2 Interface Board. IndustryPack (IP) PCMCIA / CardBus. Fax: (240) 376-1381. Phone: (217) 352-9330. VME-MXI-2 User Manual - National Instruments. 2 (kernel 2. C-Size / 6U x 340mm. Texas Instruments SFBM 1670970 Memory VME Module. This chapter introduces you to the concepts of VXI (VME eXtensions for Instrumentation), VME, MXI (Multisystem eXtension Interface), and their relationship to the NI-VXI application programmer’s interface (API). The PCI card is serial 182685J-01. UV Cure. • 16-Bit A/D Processor Card, Part Number: 01-072-003. Fieldpoint / CompactFieldpoint. are not included with this equipment unless listed in the above stock item description. 1 Front-End-Electronic For the beam-time in 2000 the readout system of the TPC was completely changed. IndustryPack (IP) PCMCIA / CardBus. Simultaneous-Sampling Multifunction DAQ National Instruments VXI-MXI-2 Interface Board National Instruments NI 9205 32-Channel Analog Input Module. National Instruments VXI-MXI-2 Interface Board. CompactRIO / CompactDAQ. Part Numbers: 1670970-9, 1670973, 1670973-1. National Instruments 778647-01 Replacement Power Supply and Fan Shuttle for NI PXI-1044/PXI-1045. National Instruments VXI-MXI-2 Interface Board. Attention! Your ePaper is waiting for publication! By publishing your document, the content will be optimally indexed by Google via AI and sorted into the right category for over 500 million ePaper readers on YUMPU. Although the manual does not mention NI-VISA, the installation procedure can Chapter 3 VXI Configuration Utility Notice that the VXI/VME-MXI-2 has a limit on the number of automatic retries it will perform on any one cycle. Keysight / Agilent E1430A VXI 10 MSa/s 23-bit Digitizer. NI-488. Hello Greg, Unfortunately, the timing of the VXI-MXI-2 cannot be adjusted to support a longer SYSRESET* assertion. / Bancomm bc635VME Time and Frequency Processor Mercury Computer Systems RACE MCJ6 VME64 Motherboard National Instruments VME-MXI-2 VMEbus Extender Interphase V/FDDI 5211 VME FDDI Adapter Module. 7. Manufacturing . • 1 Connection to E-Stop Circuits. A-Size / 3U x 160mm. UV Cure. Mercury Computer Systems RACE MCJ6 VME64 Motherboard. . D-Size / 9U x 340mm. Instead of using a 16-bit digital data link between the front-end electronics and the motherboards, on which the data were compacted and reformatted, an analog connection to the FEDC-boards 1 was used. National Instruments VXI-MXI-2 Interface Board. 05-31-2016 05:26 PM. VME-MXI-2 User Manual - National Instruments EN English Deutsch Français Español Português Italiano Român Nederlands Latina Dansk Svenska Norsk Magyar Bahasa Indonesia Türkçe Suomi Latvian Lithuanian český русский български العربية UnknownAbaco Systems / VMIC VMIVME-2131-110 64-Bit Current Source / Sink Driver Microchip / Bancomm bc635VME Time and Frequency Processor Mercury Computer Systems RACE MCJ6 VME64 Motherboard National Instruments VME-MXI-2 VMEbus Extender Interphase V/FDDI 5211 VME FDDI Adapter Module - Dual Attachment Abaco Systems / VMIC. C-Size / 6U x 340mm. PCMCIA / CardBus. Manufacturing. Vme-Mxi-2 Block DiagramResman is held up when it tries to configure the mainframe corresponding to the VME-MXI-2 device. National Instruments 778647-01 Replacement Power Supply and Fan Shuttle for NI PXI-1044/PXI-1045 National Instruments VME-MXI-2 VMEbus Extender National Instruments cFP-DI-301 Digital Input Module Emerson /. Fieldpoint / CompactFieldpoint. National Instruments VME-MXI-2 VMEbus Extender. VMESC5 IP Module Carrier Curtiss-Wright / Systran SCRAMNet A-HS-DPMCG02M-20 PMC Module Curtiss-Wright / Systran VLX2500 VME Crossbar Switch Module Emerson / Motorola MVME712M / MVME712/M I/O Transition Module. National Instruments PXI-4070 6. 1 (Windows 9x/NT/2000). Semiconductor / Wafer. C-Size / 6U x 340mm. When MAX is started. If you use 2 chassis, you could concievably read the trigger input on one chassis, and then write to the output of the other chassis, but you cannot. The network is implemented using VME-MXlbus adapter boards. ISA. National Instruments VXI-MXI-2 Interface Board. configuration in a software-transparent fashion using VXI-MXI-2 mainframe extenders. are not included with this equipment unless listed in the above stock item description. MOTOROLA MVME 162-222,01-W3913B 02A,CANON SCAN MPU BG6-7285,TIP840-20. Part Number: 183105A-01, 183105C-01, 183105A-11, 183105D-01 . Important Notice: Other accessories, manuals, cables, calibration data, software, etc. 4 GHz • Memory: 2-8 GB • Hard Drive: 160-320 GB* Part Number: EMX-2401(G)-8020 *If a specific Hard Drive or Memory Size is required, please contact Artisan Technology Group Sales for pricing and availability. I would first suggest that you check with the manufacturer of the Rubidium clock device since it is a VME spec. are not included with this equipment unless listed in the above stock item description. A-Size / 3U x 160mm. Keysight / Agilent E1430A VXI 10 MSa/s 23-bit Digitizer. All prices are shown in USD. Page 41: Parity Checking 1) The VME-MXI-2 automatically detects if it is in slot 1 and will only run Resman if it is. Connect to the PC through the network. Hello, I am using a system with the following configuration : * VME card VME-MXI-2 : 183105A-01 * cable MXI-2-1 P/N : 182801A-002 * PCI card : PCI-MXI-2 : 182685H-01 to access and test VME boards inside a VME rack. National Instruments VME-MXI-2 VMEbus Extender. B-Size / 6U x 160mm. . A-Size / 3U x 160mm. VME-MXI-2 Mainframe Extender, Remote Control Module for VXI—The Remote Control Module for VXI is a flexible, high-performance solution for stand-alone computer control of VXI systems. This entire setup was used on an older computer running Win XP professional and using MXI Visa ver 3. Part Number: MF1612054. Mercury Computer Systems PowerPC 7447A RACE++ Daughter Card. • Drive Bay: None Installed. Part Number: 90066-1-A, 90066-2-B Show More Description Important Notice: Other accessories, manuals, cables, calibration data, software, etc. For that, I created a device in MAX which is under VXI::0::INTR(PCI-MXI-2). Test System comprised of PC, MXI-2-PCI card, MXI-2-VME card, VME bus rack w/ one card under test (proprietary memory I/O). 16 Gigabit Ethernet interface. Power down crate. We endeavour to ensure availability and access to your requested instruction manuals and associated documents, at any time on behalf of our registered customers. VXI & VME. MXI / MXI-2 / MXI-3 / MXI-4. National Instruments VME-MXI-2 VMEbus Extender. VME-MXI-2 User Manual - National Instruments EN English Deutsch Français Español Português Italiano Român Nederlands Latina Dansk Svenska Norsk Magyar Bahasa Indonesia Türkçe Suomi Latvian Lithuanian český русский български العربية UnknownNational Instruments VME-MXI-2 VMEbus Extender. Kontron CP306 Pentium M Rugged CPU Controller Board. National Instruments produced the VME-MXI module. MOTOROLA VME162PA 252SE,01-W3627F 68B CPU BOARD CANON MAIN MPU BG6-7280. Show More Description. VXI & VME . In addition, there are VXI and VME Mainframes, Embedded Computers, modules, Terminal Blocks, and more. 44 MB floppy utilizing the floppy port, or a Super Floppy LS-120. A-Size / 3U x 160mm. 5T-7/S618 (U0938-20) Eurofast Cable. A-Size / 3U x 160mm. RadiSys EPC-6A High-Speed VMEbus Controller. Mercury Computer Systems RACE MCJ6 VME64 Motherboard. Part Number: 183105A-01, 183105C-01, 183105A-11, 183105D-01 . Hard Disk Test. Semiconductor / Wafer. When a tried to read a value with a V. VXI & VME . Work with our experts to sustain your critical applications. ) if you are targeting a configured device. This Motorola MVME230-3 VME Memory Module is new from surplus stock. 16 compatible to support Ethernet switched fabric backplane architectures. Overview. Mercury Computer Systems RACE MCJ6 VME64 Motherboard. Return to Home Page. Mercury Computer Systems RACE MCJ6 VME64 Motherboard. Hello, I installed a pxi-mxi-2 and a vme-mxi-2 in my computer and old test rig that was running MXI-1. Abaco Systems / SBS / Greenspring VIPC610 VMEbus IP Carrier. We have troubles with our old PCI-MXI-2 & VXI-MXI-2 cards. 5-inch IDE drives for high shock/vibration requirements, and one microfloppy. UV Cure. FCC/DOC Radio Frequency Interference Class A Compliance This equipment generates and uses radio frequency energy and, if not installed and used in strict03-10-2005 02:44 PM Options I'm trying to assist a customer who is trying to use one of our VXI products in a GenRad D-size chassis with a NI VME-MXI-2 controller. Configuration: • 1 MB CMOS SRAM. C-Size / 6U x 340mm. Important Notice: Other accessories, manuals, cables, calibration data, software, etc. National Instruments PXI-8145RT Embedded PXI Computer. / Bancomm bc635VME Time and Frequency Processor Mercury Computer Systems RACE MCJ6 VME64 Motherboard National Instruments VME-MXI-2 VMEbus Extender Interphase V/FDDI 5211 VME FDDI Adapter Module. Fieldpoint / CompactFieldpoint. I'm using Solaris and NI-VXI to talk to a VME-MXI-2 without any trouble. 3V transceivers designed for a range of high-speed bi-directional communication applications and offer nominal data rates ranging from 155Mbit/s to 2. 3. n acknowledges that the device has a base address of x0000 and has requested 4 MBytes of space in A24 space, but the bus errors were still received. VME-MXI-2 User Manual - National Instruments EN English Deutsch Français Español Português Italiano Român Nederlands Latina Dansk Svenska Norsk Magyar Bahasa Indonesia Türkçe Suomi Latvian Lithuanian český русский български العربية UnknownNational Instruments VXI-MXI-2 Interface Board. TPC Readout 2000 CERES 2000/2001 . We need to build a second test set and a new. Top Kontron / Thales / Cetia ProductsNational Instruments VXI-MXI-2 Interface Board. Downloadable Technical Manuals and Datasheets. A-Size / 3U x 160mm. VME-MXI-2 User Manual - National Instruments EN English Deutsch Français Español Português Italiano Român Nederlands Latina Dansk Svenska Norsk Magyar Bahasa Indonesia Türkçe Suomi Latvian Lithuanian český русский български العربية UnknownVXI & VME . Mercury Computer Systems RACE MCJ6 VME64 Motherboard. gtb1234. Manufacturing . The VME boards are controlled by the PCI-VME bridge, the National Instruments VME-MXI-2 bus extender [4]. Re: IPC support jdubs. C-Size / 6U x 340mm. The VXI-MXI-2 bus interface for C-size modules conforms to the VXIbus Mainframe Extender Specification (VXI-6) from the. The connection between Computer and VME is carried out through MXI-2 cable plugged in PCI card and in the VME-MXI-2 controller board. SCP. You would also need a host clock on the backplane to provide reference, there is a 10Mhz clock can be used by VXI-MXI controllers but not the VME controller. I would now like to move to Windows 7. VXI & VME . VXI & VME . Hard Disk Test. Page 15: Vme Users VXI devices,. All of them apply to VXI, but some groups are. Mercury Computer Systems RACE MCJ6 VME64 Motherboard. The NI VXI-MXI-2 (Part Number: 777178-01) is a C-size Mainframe Extender. Communication to VME systems can be done with NI-VISA or a hardware driver that was created by the manufacture. CDPID PDA Termination Tester features one 26-pin on-board connector and two 50-pin on-board connectors in a B-size VME module. 0), so we installed the NI-VXI software on Red Hat MRG Realtime 1. The failed board has been sent back to NI for repair/replacement (luckily it was under warranty). PCI / PCI Express. B-Size / 6U x 160mm. This entire setup was used on an older computer running Win XP professional and using MXI Visa ver 3. I have a VME-MXI-2 card occupying slot 0 in a VME crate. PCI / PCI Express. National Instruments 778647-01 Replacement Power Supply and Fan Shuttle for NI PXI-1044/PXI-1045. C-Size / 6U x 340mm. With the additional compatibility of PICMG 2. Trigger interrupt on VME bus via board under test (verified w/ scope), no activity on VIC screen. National Instruments VME-MXI-2 VMEbus Extender. A-Size / 3U x 160mm. constants. Part Number: 11-1011777-2119. National Instruments PXI-8145RT Embedded PXI Computer. vi. As the PCI-MXI-2 Universal card is discontinued and is no longer available, so we purchased one PCI-MXI-2 card (Part Number: 777185-01) recently. From the perspective of the MXIbus, the VME-MXI-2 implements a MXIbus interface to communicate with other MXIbus devices. Semiconductor / Wafer. PCI / PCI Express. 2 (kernel 2. The VME-MXI-2 can interconnect multiple VME chassis, enabling them to operate as a single VME system. VME-MXI-2 User Manual - National Instruments EN English Deutsch Français Español Português Italiano Român Nederlands Latina Dansk Svenska Norsk Magyar Bahasa Indonesia Türkçe Suomi Latvian Lithuanian český русский български العربية UnknownMXI / MXI-2 / MXI-3 / MXI-4. Solution: Use VXIedit to insert x4700 into registers A, C, E and 10 of the the VME-MXI. Kontron / JUMPtec PGX1L110 PC-104 Module. Attention! Your ePaper is waiting for publication! By publishing your document, the content will be optimally indexed by Google via AI and sorted into the right category for over 500 million ePaper readers on YUMPU. We have been using version V. National Instruments VXI-MXI-2 Interface Board. It talks back to a MXI card mounted in a desktop PC running Labview 7. D-Size / 9U x 340mm. but the PCI-MXI-2 came with no useful information. 2) Software running on the PC with the MXI interface deceides to call a "viIn" function in the NI visa library (and the VXI bus is busy) 3) The PC becomes "frozen" until the bus mastering is over (sometimes it spontaneously re-boots) 4) The PC comes back to life, but was "frozen in time. Thanks with regards, Umesh. Abaco Systems / Ramix CP237 Multipurpose cPCI PMC Carrier. Overview. 8. National Instruments VXI-MXI-2 Interface Board. Instruments VME-MXI-2 VMEbus Extender Mercury Computer Systems RACE MCJ6 VME64 Motherboard Interphase V/FDDI 5211 VME FDDI Adapter Module. National Instruments VME-MXI-2 VMEbus Extender. The combination of a VXI-MXI-2 and VXIbus. D-Size / 9U x 340mm. Insert the VME-MXI-2 in Slot 1 of the second mainframe. C-Size / 6U x. Memory for Allocating Data Structures Memory is needed to set up the necessary page. Curtiss-Wright / Primagraphics Sentinel 744001 VME Capture Unit. VXI & VME . / Motorola / Force Computers CPU-30ZBE SYS68K Single Board Computer Emerson / Motorola / Force Computers SYS68K/ISIO-2 VME Serial Interface Emerson / Motorola / Force Computers cPCI-690. Mercury Computer Systems RACE MCJ6 VME64 Motherboard. eric. I'm using Solaris and NI-VXI to talk to a VME-MXI-2 without any trouble. VME-MXI-2 User Manual - National Instruments. are not included with this equipment unless listed in the above stock item description. Manufacturing . Mercury Computer Systems RACE MCJ6 VME64 Motherboard. . 7-139. National Instruments PXI-8102 High-Value PXI Embedded Controller for Windows. Lycangeek. vxi-mxi-2 termination. Mercury Computer Systems 910-08163 RACE++ Series 500-MHz PowerPC 7410 Daughter Card. RadiSys PFS-302 prPMC Processor Module. 5 inch, 1. To operate as the VMEbus system controller, this interface board can be installed in the left slot of a VME chassis. This National Instruments VME-MXI-2 VMEbus Extender is used, and in excellent condition. I've had a VME-MXI-2 kit running in a VME rack very nicely for a few months. All prices are shown in USD. 1) Not all of the device functionality may be available. Hard Disk Test. SCXI. National Instruments cFP-2120 Compact FieldPoint Ethernet Controller Interface. CompactRIO / CompactDAQ. If the limit is exceeded and the VXI/VME-MXI-2 receives another retry, it will pass a retry back to the MXIbus even though VXI Auto Retry is enabled. VXI & VME. National Instruments VME-MXI-2 VMEbus Extender. VXI-MXI-2 Status Register (VMSR) For example, you can verify that you are set up in interlock mode by launching VIC, select Bus Access, and set up these parameters: Device Name VXI-MXI-2 » Operation Inreg » Register User Offset » Offset h20 . Top SecureLogix ProductsThis Vaisala MWV201 Navaid Processor Module is used and in excellent condition. Part Number: 01-W3394F 07C, 01-W3394F 07G, 01-W3839F 07C. 182801A-001 National Instruments 182801A-001 MXI-2 Type M1 Cable (1 Meters) from National Instruments | Buy Today from Artisan. The OGP GPIO-60 VME Module has a variety of features including Status LEDs, a RJ-45 Connection, and a 60-Pin Ribbon Cable Connection. VXI-MXI-2 and NI-VISA. Per user's manual (page 40), it is said that the first and last MXIBus device connects to the MXIbus. Mercury Computer Systems RACE MCJ6 VME64 Motherboard. 1. Remote Controllers Each VXI-MXI-2 has a full MITE chip set onboard. Support Worldwide Technical Support and Product Information ni. SCXI. SCXI. GE / Bently Nevada 18745-03 5 and 8 mm Proximitor Sensor. Mercury Computer Systems 910-08163 RACE++ Series 500-MHz PowerPC 7410 Daughter Card. National Instruments PCIe-8361 x1 MXI-Express Device for PXI Remote Control. This unit is a non-standard width, as shown in the accompanying pictures. SCXI. National Instruments PXIe-8379 MXI PXIe Controller ModulePart Number: 152895B-02L, 782991-01 Resma. Explore More Categories. Install the NI-VXI/VISA software as described in Chapter 5, NI-VXI Software Installation, in your getting started manual. To verify capabilities of target boards, I have to realize access with specific mode, so I use the VISA functions to modify access. CompactRIO / CompactDAQ. are not included with this equipment unless listed in the above stock item description. Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. 当SIMMs 小于4 M x 32, S2应该为打开的位置. Manufacturers. Mercury Computer Systems RACE MCJ6 VME64 Motherboard. A-Size / 3U x 160mm. Email: 931B Fluke 931B RMS Differential Voltmeter from Fluke | Buy Today from Artisan. Product Family: 5998-01-523-9361, 5998015239361. You have the VME-MXI-2 controller which does not have the TIC functionality since there is no CLK and TRIG signal output on the front panel of the controller. SCP. National Instruments VXI-MXI-2 Interface Board. NI Employee (retired)National Instruments VXI-MXI-2 Interface Board. Configuration: • 512 MB SDRAM. VME-MXI-2 User Manual - National Instruments. Part Number: 183105A-01, 183105C-01, 183105A-11, 183105D-01 Show More Description Re: Libraries to use in LabView VME modules. Important Notice: Other accessories, manuals, cables, calibration data, software, etc. Re: Libraries to use in LabView VME modules. Configuration: • Optical Connector: SC/PC. SCP. 2, VXI 3. 6, VISA 4. This VME MXI-2 Interface Kit comes with a PXI-8320 plug-in circuit board, a VME-MXI-2 interface board, a 2 m MXI-2 cable, and software for Windows. National Instruments PXI-8145RT Embedded PXI Computer. National Instruments VME-MXI-2 VMEbus Extender. National Instruments VME-MXI-2 VMEbus Extender. x 4 ni. . FORE Systems PCA-200E ATM Adapter. B-Size / 6U x 160mm. Fax: (240) 376-1381. National Instruments 782317-03 x8 Gen II MXI-Express Cable (3 Meter) This item is sealed in the manufacturer's bag. Fax: (240) 376-1381. Mercury Computer Systems RACE MCJ6 VME64 Motherboard. D-Size / 9U x 340mm. VME-MXI-2 User Manual - National Instruments EN English Deutsch Français Español Português Italiano Român Nederlands Latina Dansk Svenska Norsk Magyar Bahasa Indonesia Türkçe Suomi Latvian Lithuanian český русский български العربية UnknownNational Instruments VXI-MXI-2 Interface Board. Install the NI-VXI/VISA software as described in Chapter 5, NI-VXI Software Installation, in your getting started manual. A-Size / 3U x 160mm. Opt. B-Size / 6U x 160mm. A-Size / 3U x 160mm. Fast Quotes & Shipping. works perfectly. Abaco Systems / Ramix CP237 Multipurpose cPCI PMC Carrier. 9 full IPMI system management, the IBC 2801 is a powerful, scalable, open architecture building block in high-reliability and high-availability. Remote Controllers Each VXI-MXI-2 has a full MITE chip set onboard. The MXI-2 computer interface – for example, the PCI-MXI-2 – normally. I have a PCI-MXI-2 card that is currently in a Windows Xp computer. SCXI. NI-VXI 3. The VME-PCI80xx makes your computer perform as if it were plugged directly into the backplane, giving your external computer the capability of an embedded computer. are not included with this equipment unless listed in the above stock item description. National Instruments VME-MXI-2 VMEbus Extender. e. It's 0x1800 on power up, and the two MSBs need to be set to enable the address mapping window and the proper direction. x includes a Resource Manager, graphical and text-based versions of an interactive VXI resource editor. GPIB / USB / Firewire. The DDrive module occupies only one 6U slot in the VME card cage and requires only power from the VME Bus. The MXI network has a tree topology with the first node acting as the root (See Figure 1). CC-PAIH01 Honeywell CC-PAIH01 High Level Analog Input Module with HART from Honeywell | Buy Today from Artisan. D-Size / 9U x 340mm. 1 Show More Description Important Notice: Other accessories, manuals, cables, calibration data, software, etc. I can't configure the VME configuration manually using the tools for variuos reasons. National Instruments VME-MXI-2 VMEbus Extender. C-Size / 6U x 340mm. C-Size / 6U x 340mm. Explore More Categories. 1. Kontron CP306 Pentium M Rugged CPU Controller Board. National Instruments VXI-MXI-2 Interface Board. National Instruments PXI-8145RT Embedded PXI Computer. SCP. Semiconductor / Wafer. com. Attention! Your ePaper is waiting for publication! By publishing your document, the content will be optimally indexed by Google via AI and sorted into the right category for over 500 million ePaper readers on YUMPU. CompactRIO / CompactDAQ. GPIB / USB / Firewire. GPIB / USB / Firewire. It seems that the hardware is configured correctly in MAX, but I'm having a bit of trouble sorting out how to go about building an appropriate VI in LabView 7. The internal trigger line can only go one direction, so it makes sense that it can only be connected to one or the other. National Instruments VXI-MXI-2 Interface Board. National Instruments VME-MXI-2 VMEbus Extender. It features an NI PXI-8320 plug-in circuit board, an NI VME-MXI-2 interface board, a 2 m MXI-2 cable, and software for Windows. 03-29-2005 08:39 AM. National Instruments cFP-2120 Compact FieldPoint Ethernet Controller Interface. PCI / PCI Express. 5/125 um, Multimode. Attention! Your ePaper is waiting for publication! By publishing your document, the content will be optimally indexed by Google via AI and sorted into the right category for over 500 million ePaper readers on YUMPU. Daisy-chain. PCI / PCI Express. We have a visual basic 6 application that communicates through the cards to a VME chassis. National Instruments VXI-MXI-2 Interface Board. Running VISA 5. The VME-MXI-2 can automatically determine if it is located in the first slot of a VMEbus chassis and if it is the MXIbus System Controller. National Instruments PXI-8145RT Embedded PXI Computer. National Instruments VME-MXI-2 VMEbus Extender. UV Cure. UV Cure. Trusted Seller.